Friday, 29 August 2008

Wseas Transactions

New Subscription to Wseas Transactions

The following information was submitted:

Transactions: WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE
Transactions ID Number: 27-722
Full Name: Milan Stork
Position: Professor
Age: ON
Sex: Male
Address: University of West Bohemia, Plzen
Country: CZECH REPUBLIC
Tel: 377634243
Tel prefix: 420
Fax: 420377634202
E-mail address: stork@kae.zcu.cz
Other E-mails:
Title of the Paper: The Use of Radial Oscillometric Waveforms In Estimation of Blood Pressure and Hemodynamics
Authors as they appear in the Paper: J. Jilek, M. Stork
Email addresses of all the authors: jilekj@usa.net, stork@kae.zcu.cz
Number of paper pages: 10
Abstract: Abstract: High blood pressure is a major risk for cardiovascular disease. Blood pressure is determined by the underlying hemodynamics. An inexpensive system capable of noninvasive determination of blood pressure and hemodynamics could help to improve diagnosis and treatment of high blood pressure. A system (Carditor) for noninvasive determination of blood pressures and hemodynamics is presented. The system consists of a wrist cuff, a battery powered module with pneumatic and electronic circuits, and a notebook computer. The computer controls cuff inflation, deflation and data acquisition functions during gradual cuff deflation. Proprietary software is used to analyze oscillometric waveforms obtained from the radial artery. Systolic, mean and diastolic blood pressures and stroke volume are computed first. Stroke volume is then adjusted for body area and the adjusted value is used to compute cardiac output. Total peripheral resistance and systemic arterial complianc!
e are computed from arterial pressures, cardiac output and stroke volume. The computed hemodynamic variables are displayed on the computer screen in a "quadrant" graphic form. Preliminary hemodynamic data from from a group of 41 men and women (age 17-76) were used for qualitative comparison with published data (deSimone, n=544). Carditor results: stroke volume=76 ml, heart rate=70 bpm, cardiac output=5.3 l/min. DeSimone results: stroke volume=81 ml, heart rate=68 bpm, cardiac output=5.5 l/min. Examples of test results and clinical applications of the system are discussed.
Keywords: Bioimpedance, blood pressure, hemodynamics, microcontroller, oscillometric waveforms, sensor.
EXTENSION of the file: .pdf
Special (Invited) Session: Determination of Blood Pressure and Hemodynamics from Oscillometric Waveforms
Organizer of the Session: 591-177
How Did you learn about congress: Martin poupa - poupa@kae.zcu.cz, Josef Hrusak - hrusak@kae.zcu.cz
IP ADDRESS: 147.228.95.135